FC-SAI-1620 Product datasheet
Model number: |
FC-SAI-1620M |
|
Module Type: |
Analog input module |
Manufacture: |
Honeywell |
|
Condition: |
Brand New |
Range of Product: |
Safety Manager System |
|
Lead time: |
In Stock |
Weight: |
0.14kg |
|
HS CODE: |
8537101190 |
Dimension: |
2x19x12.8cm |
|
MOQ: |
1 |
Product Origin: |
USA |
|
System: |
DCS |
Discontinued on: |
Dec 31,2018 |
|
Communication Service: |
Ethernet router |
FC-SAI-1620 Functional Description
The FC-SAl-1620M analog input module is designed to offer sixteen safe analog input channels (0-4V) compliant with SlL3 safety class as per lEC61508 standards. It is ideal for applications requiring high-density and high-safety analog input solutions. Controlled by the Safety Manager Controller, it performs self-tests to ensure absolute accuracy, correct conversion over the full range, checks for crosstalk between inputs, channel input filters,and internal supply voltages.
The Honeywell FC-SAI-1620M is a 16-channel analog input module for the Safety Manager system. It provides 24 VDC power to each channel and accepts 0(4)-20 mA input signals. The module is mounted in a card cage and can be configured to monitor a variety of process variables, such as temperature, pressure, and flow.
The Honeywell FC-SAI-1620M is a Safety Manager System Module that provides a comprehensive solution for safety management in industrial automation systems. Safety Manager™ is available in several configurations to suit virtually every process control requirement.Safety Manager can be configured for a number of architectures, each with its own characteristics and typical applications. The DMR architecture with 1oo2 voting is based on dual processor technology, and is characterized by a high level of self tests, diagnostics and fault tolerance. The DMR architecture is realized with a non-redundant Controller.
If you have other request contact our team to get customized service
ABB |
DSQC601 3HAC12815-1 |
ABB |
DSQC639 3HAC025097-001 |
ABB |
DSQC601 3HAC12815-1 |
ABB |
DSQC697 3HAC037084-001 |
ABB |
DSQC639 3HAC025097-001 |
ABB |
DSQC562 3HAC16014-1 |
ABB |
DSQC697 3HAC037084-001 |
ABB |
DSQC639 3HAC025097001 |
ABB |
DSQC541 3HAC14363-1 |
ABB |
DSQC679 3HAC028357-001 |
ABB |
DSQC637 3HAC023047-001 |
ABB |
DSQC532B 3HAC023447-001 |
ABB |
DSQC663 3HAC029818-001 |
ABB |
DSQC627 3HAC020466-001 |
ABB |
DSQC503 3HAC3619-1 |
ABB |
DSQC662 3HAC026254-001 |
ABB |
DSQC625 3HAC020464-001 |
ABB |
DSQC500 3HAC3616-1 |
ABB |
DSQC658 3HAC025779-001 |
ABB |
DSQC611 3HAC13389-2 |
ABB |
DSQC406 3HAC035301-001 |
ABB |
DSQC652 3HAC025917-001 |
ABB |
DSQC609 3HAC14178-1 PBSE5117 |
ABB |
DSQC378B 3HNE00421-1 |
ABB |
DSQC651 3HEA800439-002 |
ABB |
DSQC608 3HAC12934-1 |
ABB |
DSQC373 3HAC3180-1 |
ABB |
DSQC643 3HAC024488-001 |
ABB |
DSQC604 3HAC12928-1 |
ABB |
DSQC363 3HAC1462-1 |
Safety Manager Introduction
Safety Manager combines Honeywell’s proven Quadruple Modular Redundancy (QMR®) 2oo4D technology with extensiveprocess safety management expertise in integrating process safety data, applications, system diagnostics and critical control strategies.
Honeywell’s IEC 61511 and IEC 61508 SIL 3 TÜV certified solution provides the optimal level of safety and process integration while still maintaining functional safety separation as mandated by those standards. Through Experion operational integration, all systems are unified into one operationally integrated architecture, providing a unique opportunity to improve safety, process availability and efficiency. Experion provides unprecedented connectivity through all levels of process and business operations to optimize work processes, improve routine maintenance efficiencies, enhance safety management and release personnel from manual processes.
Safety Manager Features
Safe and Secure – Safety Manager is designed to be securely integrated into customer systems and has passed very rigorous security testing as defined by ISA Security Compliance Institute (ISCI). Safety Manager was the first safety system to achieve Embedded Device Security Assurance (EDSA) certification. ISCI developed this certification within the framework of the ISA Industrial Automation and Control Systems security standards (ISA 99). Because of the built in protection mechanisms, the Experion Safety Manager is protected from cyber attacks and disruption of service.
High Availability Architecture – Honeywell’s field-proven QMR 2oo4D architecture provides the highest availability with a safe architecture. Applying QMR technology allows uninterrupted process operation in the event of any system degradation or on-process modification without jeopardizing the SIL 3 level. The optional Safety Manager A.R.T. (Advanced Redundancy Technique) provides additional benefits for locations where timely maintenance is not available.
Easy and Intuitive Engineering and Modifications – Safety Builder, an intuitive and comprehensive configuration tool, provides plant-wide management of safety-critical databases and application programming for easy network design. TÜVapproved, menu-driven online modifications prevent errors while maintaining and optimizing the safety application.
Defense-in-Depth – SafeNet and remote distributed Safety Manager provide the ability to design defense-in-depth safety strategies that maximize safety and security while minimizing risk and scope-of-loss concerns.
Safety Networking - The networking capabilities of Safety Manager are unsurpassed. Up to 1024 redundant nodes can be included in one safety network, acting as one integrated safety solution. The SIL 4 certified SafeNet communication protocol guarantees fast and safe communication over any media and distance. The remote management capabilities support centralized management of all connected safety systems.