MU-TAMR03 51309218-125 Product datasheet
Model number: |
MU-TAMR03 51309218-125 |
|
Module Type: |
Low Level Analog Mux Module |
Manufacture: |
HONEYWELL |
|
Condition: |
Brand New |
Range of Product: |
MU-T Series |
|
Lead time: |
In Stock |
Weight: |
0.78kg |
|
HS CODE: |
8537101190 |
Dimension: |
12.1x5x30.8cm |
|
MOQ: |
1 |
Product Origin: |
USA |
|
System: |
DCS |
Discontinued on: |
active |
|
Communication Service: |
Ethernet router |
MU-TAMR03 51309218-125 Functional Description
If you have other request contact our team to get customized service
Honeywell |
MU-TSIM12 51303932-426 |
Honeywell |
MU-TAMT03 51309223-125 |
Honeywell |
MC-TSTX13 51309142-175 |
Honeywell |
MU-TSIM12 51303932-401 |
Honeywell |
MU-TAMT02 51401491-100 |
Honeywell |
MC-TSTX13 51309142-175 |
Honeywell |
MU-TSDM02 51303932-277 |
Honeywell |
MU-TAMR03 51309218-125 |
Honeywell |
MC-TSTX03 51309140-175 |
Honeywell |
MU-TPIX12 51304084-100 |
Honeywell |
MU-TAIH12 51304337-100 |
Honeywell |
51304386-150 MC-PPIX02 |
Honeywell |
MU-TLPA02 51309204-125 |
Honeywell |
MU-TAIH02 51304453-100 |
Honeywell |
MC-TSIM12 51303932-476 |
Honeywell |
MU-TDOR22 51309150-125 |
Honeywell |
MU-PLAM02 51304362-100 |
Honeywell |
MC-TPIX12 51304084-175 |
Honeywell |
MU-TDOA13 51304648-100 |
Honeywell |
MU-PDIX02 51304485-100 |
Honeywell |
51304754-150 MC-PAIH03 |
Honeywell |
MU-TDID12 51304441-125 |
Honeywell |
MU-PAOX03 51304672-100 |
Honeywell |
MC-TLPA02 51309204-175 |
Honeywell |
MU-TAOX12 51304335-100 |
Honeywell |
MU-FOED02 51197564-200 |
Honeywell |
MC-TDOY23 51204166-175 |
Honeywell |
MU-TAOX02 51304476-125 |
Honeywell |
MU-KBFT02 80366198-200 |
Honeywell |
MC-TDOY22 51204162-175 |
MU-T Series UPS Introduction
The UPS consists of a battery charger, a large battery, and a chopper to convert the battery’s dc power into quality ac power. The UPS is always on and is always supplying power to its load through the battery that is on a float charge. Should the ac input fail, the UPS continues to serve the load without any changes and it will continue to operate until the battery is discharged, or the ac input to the UPS charger is restored. The capacity of the battery pack is specified by the UPS manufacturer and will provide many hours of backup.
UPS transfer switches
The UPS usually has two transfer switches. A switch on the output of the UPS automatically transfers the loads to plant power in case of failure in the UPS. A second transfer switch to the UPS input charger allows manual transfer to public utility power if there is extended failure of plant power. A UPS with two ac sources provides the means for several backup strategies. The HPM offers additional permutations with its optional redundant Power Supply Modules, dual-feeds, and battery backup. The need for all of this backup redundancy depends on how important it is to have a working control system when plant power is out for an extended period.