IS220YDOAS1A Functional Description    


The IS220YDOAS1A is a discrete output pack module designed to interface with both a discrete output terminal board and up to two I/O Ethernet networks. This module consists of two primary components: an acquisition board and a common processor board, both essential for supporting discrete output operations. A standout feature of the IS220YDOAS1A is its capability to control up to twelve relays and receive feedback from the terminal boards. The output is transmitted through a DC-37 pin connector, providing direct connection to the associated terminal board.

 

The IS220YDOAS1A Control Discrete Output Module can be configured in either TMR or simplex redundancy setups. For TMR applications, three I/O packs are required, while only one pack is needed in simplex configurations. This pack is equipped with self-diagnostic capabilities, including a power-up test that checks the processor board hardware, flash memory, Ethernet ports, and RAM. The diagnostic results are accessible through the ToolboxST application.

 

Status indicators are provided by twelve LEDs on the IS220YDOAS1A Mark VI PCB Board Assembly, each signaling the presence of a command to energize the corresponding relay. These LEDs turn yellow when indicating active outputs. Additionally, the IS220YDOAS1A includes specific alarms to monitor potential issues. One example is the 142 alarm, which indicates a lack of terminal board excitation or blown fuses. In the event of this alarm, the recommended solution is to replace either the I/O pack or the terminal board entirely.

 

This design ensures reliable performance and ease of maintenance for systems utilizing the IS220YDOAS1A discrete output pack.

If you have other request contact our team to get customized service


  •       One Year Warranty

    We offer a one-year warranty for any quality issues with our products. If you encounter any defects or malfunctions during this period, please contact us for prompt resolution. Our warranty covers repairs or replacements, ensuring your satisfaction and peace of mind.

  •         Shipping & Delivery

    We have 10 years experience with leading logistics companies like FedEx, DHL, and SF, ensuring efficient and reliable shipping solutions. Our extensive experience in working with these carriers allows us to offer fast, secure delivery services, tailored to meet the diverse needs of our customers.
  • #

                Payment Method

    We accept a variety of payment methods, including T/T Bank Transfer, Alipay, and more, providing flexible options to suit our customers' preferences. This ensures a convenient and secure transaction process for all orders.
 
How Can I Get Your Support?
Call +86 18159889985 to be connected with our Manager Stella
     Email to sales6@apterpower.com get your best quotation
    For the quick assistance message us on WhatsApp at +86 18159889985 now!
    You can also reach me via Skype: live:ariatang111 or WeChat: zxd18159889985!
 

 

GE

DS200LDCCH1ALA

GE

DS200FSAAG1A

GE

DS200DTBBG1ABB

GE

DS200LDCCH1

GE

DS200FCSAG2ACB

GE

DS200DSPCH1ADA

GE

DS200KLDCG1AAA

GE

DS200FCSAG2A

GE

DS200DSPCH1ADA

GE

DS200KLDCG1A

GE

DS200FCSAG1A

GE

DS200DMCBG1AJE

GE

DS200KLDBG1A

GE

DS200FCSAG1ACB

GE

DS200DDTBG2ABB

GE

DS200KLDBG1ABC

GE

IS220PRTDH1A

GE

DS200CTBAG1ADD

GE

DS200GDPAG1A

GE

IS220YDIAS1AK

GE

DS200CPCAG1ABB

GE

DS200GDPAG1AEB

GE

DS200EXPSG1ACB

GE

DS200ADMAH1AAC

GE

DS2020FECNRX010A

GE

DS200DTBDG1ABB

GE

DS200ADPBG1ABB

GE

DS200FSAAG1ABA

GE

DS200DTBCG1AAA

GE

DS200ADGIH1AAA

 

 

GE Gas Turbine Control System


The GE Mark VI system is a comprehensive control solution used primarily in power generation and other industrial applications. It controls, protects, and monitors gas and steam turbines, generators, and auxiliary systems.

The SPEEDTRONIC™ Mark VI turbine control is the current state-of-the-art control for GE turbines that have a heritage of more than 30 years of successful operation. It is designed as a complete integrated control, protection, and monitoring system for generator and mechanical drive applications of gas and steam turbines. It is also an ideal platform for integrating all power island and balance-of-plant controls. Hardware and software are designed with close coordination between GE’s turbine design engineering and controls engineering to insure that your control system provides the optimum turbine performance and you receive a true “system” solution. With Mark VI, you receive the benefits of GE’s unmatched experience with an advanced turbine control platform. 

 

The heart of the control system is the Control Module, which is available in either a 13- or 21- slot standard VME card rack. Inputs are received by the Control Module through termination boards with either barrier or box-type terminal blocks and passive signal conditioning. Each I/O card contains a TMS320C32 DSP processor to digitally filter the data before conversion to 32 bit IEEE-854 floating point format. The data is then placed in dual port memory that is accessible by the on-board C32 DSP on one side and the VME bus on the other. In addition to the I/O cards, the Control Module contains an “internal” communication card, a main processor card, and sometimes a flash disk card. Each card takes one slot except for the main processor that takes two slots. Cards are manufactured with surface-mounted technology and conformal coated per IPC-CC830. I/O data is transmitted on the VME backplane between the I/O cards and the VCMI card located in slot 1. The VCMI is used for “internal” communications between:

■ I/O cards that are contained within its card rack

■ I/O cards that may be contained in expansion I/O racks called Interface Modules

■ I/O in backup <P> Protection Modules

■ I/O in other Control Modules used in triple redundant control configurations

 

■ The main processor card


Triple Redundancy

Mark VI control systems are available in Simplex and Triple Redundant forms for small applications and large integrated systems with control ranging from a single module to many distributed modules. The name Triple Module Redundant (TMR) is derived from the basic architecture with three completely separate and independent Control Modules, power supplies, and IONets. Mark VI is the third generation of triple redundant control systems that were pioneered by GE in 1983. System throughput enables operation of up to nine, 21-slot VME racks of I/O cards at 40 ms including voting the data. Inputs are voted in software in a scheme called Software Implemented Fault Tolerance (SIFT). The VCMI card in each Control Module receives inputs from the Control Module back-plane and other modules via “its own” IONet. Data from the VCMI cards in each of the three Control Modules is then exchanged and voted prior to transmitting the data to the main processor cards for execution of the application software. Output voting is extended to the turbine with three coil servos for control valves and 2 out of 3 relays for critical outputs such as hydraulic trip solenoids. Other forms of output voting are available, including a median select of 4-20ma outputs for process control and 0- 200ma outputs for positioners. Sensor interface for TMR controls can be either single, dual, triple redundant, or combinations of redundancy levels. The TMR architecture supports riding through a single point failure in the electronics and repair of the defective card or module while the process is running. Adding sensor redundancy increases the fault tolerance of the overall “system.” Another TMR feature is the ability to distinguish between field sensor faults and internal electronics faults. Diagnostics continuously monitor the 3 sets of input electronics and alarms any discrepancies between them as an internal fault versus a sensor fault. In addition, all three main processors

continue to execute the correct “voted” input data,More info pls check GEH-6005 datasheet

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit

Need Help? Chat with us

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit
Looking for News&Events?
Contact Us #
+8618159889985

Our hours

Mon 11/21 - Wed 11/23: 9 AM - 8 PM
Thu 11/24: closed - Happy Thanksgiving!
Fri 11/25: 8 AM - 10 PM
Sat 11/26 - Sun 11/27: 10 AM - 9 PM
(all hours are Eastern Time)

Home

Products

whatsApp

contact