IS230TRLSH2B Product datasheet
Model number: |
IS230TRLSH2B |
|
Module Type: |
Relay Output Module |
Manufacture: |
GE |
|
Condition: |
Brand New |
Range of Product: |
EX2100 |
|
Lead time: |
In Stock |
Weight: |
2.92 kg |
|
HS CODE: |
8537101190 |
Dimension: |
34x22.5x11.5cm |
|
MOQ: |
1 |
Product Origin: |
USA |
|
System: |
DCS |
Discontinued on: |
Active |
|
Communication Service: |
Ethernet router |
IS230TRLSH2B Functional Description
The IS230TRLSH2B relay output module, designed for GE Fanuc's Mark VIe control system, ensures reliable switching functionality in industrial automation. It features 12 Form C relays and operates on a 24 VDC power supply. With a compact size of approximately 340 mm x 216 mm x 55 mm and a weight of around 1 kg, IS230TRLSH2B is built for efficiency and durability in demanding environments.
This IS230TRLSH2B Relay Output Module is engineered to meet high-performance standards, making it ideal for industrial control applications. IS230TRLSH2B provides stable and consistent operation, ensuring seamless integration with automation systems. Its robust design enhances reliability, making it a preferred choice for industries requiring precise control solutions.
When purchasing IS230TRLSH2B Advanced Control Solutions, it is essential to choose reputable suppliers to guarantee authenticity and quality. Trusted vendors typically offer new, original units with a 12-month warranty. Buyers should ensure the availability of essential documents, such as certificates of origin and compliance, for smooth procurement and export.
Order quantities for IS230TRLSH2B generally start at a minimum of one unit. Suppliers with stock can typically deliver within 1-3 days after payment confirmation. Most transactions require 100% T/T (telegraphic transfer) prepayment. Standard warranty terms for new products usually cover one year, providing additional assurance of reliability.
General Electric IS230TRLSH2B is a dependable relay output module designed for industrial automation needs. Choosing a reliable supplier ensures product quality and strong after-sales support, making it an excellent investment for automation and control systems.
If you have other request contact our team to get customized service
GE |
DS200LDCCH1ALA |
GE |
IS220YDOAS1AJ |
GE |
DS200DTBBG1ABB |
GE |
DS200LDCCH1 |
GE |
IS200JPDMG1ADC |
GE |
DS200DSPCH1ADA |
GE |
DS200KLDCG1AAA |
GE |
IS200SRLYH2AAA |
GE |
DS200DSPCH1ADA |
GE |
DS200KLDCG1A |
GE |
IS200SRTDH2ACB |
GE |
IS420ESWBH2A |
GE |
DS200KLDBG1A |
GE |
IS200SRLYH2AAA |
GE |
IS220PDIAH1A |
GE |
DS200KLDBG1ABC |
GE |
IS220PRTDH1A |
GE |
DS200CTBAG1ADD |
GE |
DS200GDPAG1A |
GE |
IS220YDIAS1AK |
GE |
DS200CPCAG1ABB |
GE |
DS200GDPAG1AEB |
GE |
IS200TBAIS1CED |
GE |
DS200ADMAH1AAC |
GE |
DS2020FECNRX010A |
GE |
IS200TRLYS1BGG |
GE |
DS200ADPBG1ABB |
GE |
DS200FSAAG1ABA |
GE |
IS400JPDHG1ABB |
GE |
DS200ADGIH1AAA |
GE Gas Turbine Control System
The GE Mark VI system is a comprehensive control solution used primarily in power generation and other industrial applications. It controls, protects, and monitors gas and steam turbines, generators, and auxiliary systems.
The SPEEDTRONIC™ Mark VI turbine control is the current state-of-the-art control for GE turbines that have a heritage of more than 30 years of successful operation. It is designed as a complete integrated control, protection, and monitoring system for generator and mechanical drive applications of gas and steam turbines. It is also an ideal platform for integrating all power island and balance-of-plant controls. Hardware and software are designed with close coordination between GE’s turbine design engineering and controls engineering to insure that your control system provides the optimum turbine performance and you receive a true “system” solution. With Mark VI, you receive the benefits of GE’s unmatched experience with an advanced turbine control platform.
The heart of the control system is the Control Module, which is available in either a 13- or 21- slot standard VME card rack. Inputs are received by the Control Module through termination boards with either barrier or box-type terminal blocks and passive signal conditioning. Each I/O card contains a TMS320C32 DSP processor to digitally filter the data before conversion to 32 bit IEEE-854 floating point format. The data is then placed in dual port memory that is accessible by the on-board C32 DSP on one side and the VME bus on the other. In addition to the I/O cards, the Control Module contains an “internal” communication card, a main processor card, and sometimes a flash disk card. Each card takes one slot except for the main processor that takes two slots. Cards are manufactured with surface-mounted technology and conformal coated per IPC-CC830. I/O data is transmitted on the VME backplane between the I/O cards and the VCMI card located in slot 1. The VCMI is used for “internal” communications between:
■ I/O cards that are contained within its card rack
■ I/O cards that may be contained in expansion I/O racks called Interface Modules
■ I/O in backup <P> Protection Modules
■ I/O in other Control Modules used in triple redundant control configurations
■ The main processor card
Triple Redundancy
Mark VI control systems are available in Simplex and Triple Redundant forms for small applications and large integrated systems with control ranging from a single module to many distributed modules. The name Triple Module Redundant (TMR) is derived from the basic architecture with three completely separate and independent Control Modules, power supplies, and IONets. Mark VI is the third generation of triple redundant control systems that were pioneered by GE in 1983. System throughput enables operation of up to nine, 21-slot VME racks of I/O cards at 40 ms including voting the data. Inputs are voted in software in a scheme called Software Implemented Fault Tolerance (SIFT). The VCMI card in each Control Module receives inputs from the Control Module back-plane and other modules via “its own” IONet. Data from the VCMI cards in each of the three Control Modules is then exchanged and voted prior to transmitting the data to the main processor cards for execution of the application software. Output voting is extended to the turbine with three coil servos for control valves and 2 out of 3 relays for critical outputs such as hydraulic trip solenoids. Other forms of output voting are available, including a median select of 4-20ma outputs for process control and 0- 200ma outputs for positioners. Sensor interface for TMR controls can be either single, dual, triple redundant, or combinations of redundancy levels. The TMR architecture supports riding through a single point failure in the electronics and repair of the defective card or module while the process is running. Adding sensor redundancy increases the fault tolerance of the overall “system.” Another TMR feature is the ability to distinguish between field sensor faults and internal electronics faults. Diagnostics continuously monitor the 3 sets of input electronics and alarms any discrepancies between them as an internal fault versus a sensor fault. In addition, all three main processors
continue to execute the correct “voted” input data,More info pls check GEH-6005 datasheet