T8451 Product datasheet
Model number: |
T8451 |
|
Module Type: |
Digital Output Module |
Manufacture: |
ICS Triplex |
|
Condition: |
Brand New |
Range of Product: |
Trusted TMR System |
|
Lead time: |
In Stock |
Weight: |
1.26kg |
|
HS CODE: |
8537101190 |
Dimension: |
3x30.2x26.3cm |
|
MOQ: |
1 |
Product Origin: |
USA |
|
System: |
DCS |
Discontinued on: |
Dec 31,2018 |
|
Communication Service: |
Ethernet router |
T8451 Functional Description
The T8451C Digital Output Module from ICS is a highly reliable solution designed to enhance industrial automation systems with robust digital signal output capabilities. Supporting up to 24 channels, the T8451C is ideal for a wide range of applications across diverse industries, from manufacturing to process control.
Built for durability, the T8451C features a compact design that ensures stable operation even in harsh environmental conditions. With an operating temperature range of -20°C to +60°C, the T8451C is well-suited for challenging industrial environments. It also meets international safety standards, including CE and UL certifications, ensuring that it provides a high level of safety and reliability.
The T8451C is equipped with advanced circuitry, enabling it to handle complex tasks with precision. This makes it perfect for applications that require fine control over machinery and equipment. Additionally, the T8451C boasts low power consumption and efficient heat dissipation, contributing to a longer service life and reduced maintenance costs, making it an excellent choice for cost-conscious operations that demand high performance and longevity.
The data of T8451
The T8451 I/O Complex Equipment Definition includes eight I/O boards, referenced numerically by Rack number:
Rack |
I/O Board |
Description |
Data Type |
Direction |
No. ofChannels |
1 |
DO |
OEM Parameters |
|
|
|
|
|
Field Output Status |
Boolean |
Out |
40 |
2 |
STATE |
Field Output State |
Integer |
In |
40 |
3 |
AI |
Output voltage |
Integer |
In |
40 |
4 |
CI |
Output current |
Integer |
5 |
40 |
5 |
LINE_FLT |
Line Fault Status |
Boolean |
u |
40 |
5 |
DISCREP |
Channel Discrepancy |
Integer |
In |
3 |
7 |
HKEEPING |
Housekeeping Registers |
Integer |
In |
57 |
8 |
INFO |
I/O Module Information |
Integer |
In |
11 |
If you have other request contact our team to get customized service
ABB |
DSQC601 3HAC12815-1 |
ABB |
DSQC639 3HAC025097-001 |
ABB |
DSQC601 3HAC12815-1 |
ABB |
DSQC697 3HAC037084-001 |
ABB |
DSQC639 3HAC025097-001 |
ABB |
DSQC562 3HAC16014-1 |
ABB |
DSQC697 3HAC037084-001 |
ABB |
DSQC639 3HAC025097001 |
ABB |
DSQC541 3HAC14363-1 |
ABB |
DSQC679 3HAC028357-001 |
ABB |
DSQC637 3HAC023047-001 |
ABB |
DSQC532B 3HAC023447-001 |
ABB |
DSQC663 3HAC029818-001 |
ABB |
DSQC627 3HAC020466-001 |
ABB |
DSQC503 3HAC3619-1 |
ABB |
DSQC662 3HAC026254-001 |
ABB |
DSQC625 3HAC020464-001 |
ABB |
DSQC500 3HAC3616-1 |
ABB |
DSQC658 3HAC025779-001 |
ABB |
DSQC611 3HAC13389-2 |
ABB |
DSQC406 3HAC035301-001 |
ABB |
DSQC652 3HAC025917-001 |
ABB |
DSQC609 3HAC14178-1 PBSE5117 |
ABB |
DSQC378B 3HNE00421-1 |
ABB |
DSQC651 3HEA800439-002 |
ABB |
DSQC608 3HAC12934-1 |
ABB |
DSQC373 3HAC3180-1 |
ABB |
DSQC643 3HAC024488-001 |
ABB |
DSQC604 3HAC12928-1 |
ABB |
DSQC363 3HAC1462-1 |
Trusted Triple Modular Redundant (TMR) Introduction
The Trusted Triple Modular Redundant (TMR) System has been designed and certified for use in safety-related applications. To ensure that systems build upon these foundations, it is necessary to impose requirements on the way such systems are designed, built, configured, tested, installed, and commissioned, operated, maintained, and de-commissioned. This manual sets out the requirements to be met during these stages of a safety-related system to ensure that the safety-related objectives of a Trusted TMR System are achieved. This manual is intended primarily for system integrators and is not intended to be a substitute for expertise or experience in safety-related systems. It is assumed that the reader has a thorough understanding of the intended application and can translate readily between the generic terms used within this manual and the terminology specific to the integrator’s or project’s application area.
Purpose of Trusted Triple Modular Redundant (TMR)
The Trusted Triple Modular Redundant (TMR) System has been designed and certified for use in safety-related applications. To ensure that systems build upon these foundations, it is necessary to impose requirements on the way such systems are designed, built, configured, tested, installed, and commissioned, operated, maintained, and de-commissioned. This manual sets out the requirements to be met during these stages of a safety-related system to ensure that the safety-related objectives of a Trusted TMR System are achieved. This manual is intended primarily for system integrators and is not intended to be a substitute for expertise or experience in safety-related systems. It is assumed that the reader has a thorough understanding of the intended application and can translate readily between the generic terms used within this manual and the terminology specific to the integrator’s or project’s application area. Safety Integrity Level (SIL) as defined in the International Electrotechnical Commission (IEC) standard: IEC 61508-4: 2010; Section 3.5.8 is used throughout industry and it is respected by the safety community